AccuTOF™ GCv Time-of-Flight Mass Spectrometer

JEOL AccuTOF-GCv Time-of-Flight GC Mass SpectrometerHighest sensitivity GC/MS with high speed acquisition and high resolution

The AccuTOF-GCv features the highest sensitivity (S/N >100 at OFN 1 pg/µL) of any time-of-flight Gas Chromatography Mass Spectrometer commercially available. High resolution and mass accuracy allow for rapid elemental composition determination and target compound identification. The AccuTOF-GCv combines high-speed acquisition of 25 averaged spectra per second with high mass resolving power of 6000 FWHM and mass accuracy of 5 ppm or better to deliver high-resolution, accurate mass spectra with full mass range sensitivity for both qualitative and quantitative analysis. With a fast analog to digital converter providing high linear dynamic range the JEOL, the AccuTOF-GCv is perfectly suited for analyzing complex mixtures of true unknowns — even at low concentrations. Applications include: environmental, petroleum, polymers and materials, forensics, foods, flavors, and fragrances.

Multiple ionization methods

The AccuTOF-GCv is designed for optimum throughput, operation, and uptime. An optional combination EI/FI/FD ion source eliminates the need for source exchange for these experiments. Gas chromatography/field ionization can also be used to characterize difficult samples.

Standard: Electron Impact (EI)
Optional: Chemical Ionization (CI)
  Field Desorption (FD)
  Field Ionization (FI)
  Combination EI/FI/FD
  Direct Probe (exposure and insertion)
  Liquid Injection Field Desorption Ionization (LIFDI)

Automated performance optimization

Automatic ion source tuning, drift calibration, data file conversion and export optimize the speed and performance of the AccuTOF-GCv.

Compact footprint

An integrated chassis consolidates all requisite spectrometer components, including vacuum pumps, into a compact footprint. Temperature-sensitive components remain under controlled conditions and overall instrument stability and experimental reproducibility are greatly enhanced. The AccuTOF-GCv is also uniquely designed to remove 99% of He carrier gas ions before they enter the flight tube. Since the bulk of the carrier gas ions never reach the detector, the MCP lifetime is maximized.

Learn More

How does the AccuTOF GCv technology work?

Read the comprehensive article - Features and applications of Newly-Developed GC TOF/MS “The AccuTOF GC”.

Interested in a benchtop, high-resolution magnetic sector GC/MS? Take a look at GCmate II.

Application Notes
Analysis of Advanced materials by FD-FI using AccuTOF GC (Part I)
3/25/2010 127.7 KB
Analysis of Advanced materials by FD-FI using AccuTOF GC (Part II)
3/25/2010 113.2 KB
Analysis of Advanced materials by FD-FI using AccuTOF GC (Part III)
3/25/2010 71.5 KB
Analysis of Advanced materials by FD-FI using AccuTOF GC (Part IV)
3/25/2010 69.4 KB
Degradation of rotary vacuum pump oil determined by field desorption (FD) - TOFMS and group-type analysis software
4/14/2010 87.4 KB
Analysis of acrylic resin by pyrolysis GC-TOFMS
4/14/2010 228.0 KB
Analysis of photo polymerization initiator in UV light curing adhesives by GC-TOFMS
4/14/2010 140.1 KB
Analysis of block copolymer by field desorption (FD) using JMS-T100GC AccuTOF GC
4/22/2010 138.7 KB
Rapid analysis using inactivated fused silica tube (a.k.a. “guard column”) as a sample inlet (1)
4/22/2010 125.5 KB
Rapid analysis using inactivated fused silica tube (a.k.a. “guard column”) as a sample inlet (2)
4/22/2010 201.6 KB