Analytical Instrument Documents

Analysis of Additives in Plastic by Thermal Desorption (TD)

Among the various methods used for characterizing plastics, pyrolysis (Py) GC/MS and thermal desorption (TD) GC/MS are widely used for both qualitative and quantitative analyses. These are simple techniques that provide detailed information about the samples. In this application note, we report the analysis of additives in plastic by using a thermal desorption system and a JEOL JMS-T100GCV "AccuTOF GCv" GC-TOFMS. Identification of the analytes was accomplished by library search and accurate mass measurement. Additionally, isotope cluster pattern matching was performed using the "Mass Spec Tools™" software to help identify an unknown compound that was present in the sample.

Synthetic Polymer Structure Analysis - Poly Propylene Glycol

The JMS-S3000 "SpiralTOF™" is a MALDI-TOFMS that incorporates an innovative SpiralTOF ion optics system. The JMS-S3000 is available with a TOF-TOF option that can acquire high-energy collision-induced dissociation (CID) product ion spectra for monoisotopically selected precursor ions.

Fraction base-KMD plots for a high-MW - S3000 - MSTips - 2831

High molecular weight polymers are often MS-silent due to their inherent high dispersity (DM) or detected in the high mass range with low resolving power. An "on-plate" alkaline degradation has thus been developed as a sample pre-treatment on the MALDI target with tenths of ng of polymer to cut long industrial polyester chains into short oligomers amenable to MALDI-HRMS.

Introduction of the JMS-3000 SpiralTOF - Analysis of Bovine Serum Albumin

The JMS-S3000 "SpiralTOF™" is a MALDI-TOF MS incorporating an innovative SpiralTOF™ ion optics system. JEOL's patented technology achieves a spiral ion trajectory of 17m within a compact 1m space.

Structural analysis of PET combining an on-plate alkaline degradation method & tandem TOFMS - MSTips 311

We investigated the structural analysis of the polyethylene-terephthalate (PET) polymer exposed to the on-plate alkaline degradation method by using the JMS-S3000 "SpiralTOFTM-plus" with TOF-TOF option. The SpiralTOFTM-plus uses an ultra-high resolution TOF for MS1 which allows monoisotopic precursor selection and a reflectron TOF for MS2 to analyze the product ion spectra produced from high energy collisional induced dissociation (HE-CID).

Integrated Analysis of a Vinyl Acetate Resin using Pyrolysis GC-HRMS - MSTips 275

In this work, we introduce the msFineAnalysis software and use it to automatically combine data acquired by GC/EI and GC/soft ionization for the qualitative analysis of compounds produced by the pyrolysis of a vinyl acetate resin.

Degradation analysis of PET film by UV irradiation using MALDI-MSI & FE-SEM-HS05

In this report, we have applied this combined method to analyze a polyethylene terephthalate (PET) that was degraded by ultraviolet (UV) irradiation.

Proteins using spiral mode S3000 - MSTips 297

In this study, we used the JMS-S3000 to test several matrices for PSD effects and to measure high resolution mass spectra of intact insulin, ubiquitin and cytochrome C.

MS imaging for visualizing synthetic polymers using average MW and p as indices - MSTips 305

In this report, we investigate a MSI visualization method for synthetic polymers that uses Mn, Mw and D as indices for visualization.

Integrated Analysis of Fatty Acid Methyl Esters using msFineAnalysis v2 - MSTips 301

Fatty acid methyl esters (FAMEs) are crucial for determining the fat content in food. Being environmentally friendly, they are also increasingly used as bio-diesel fuels. Many of the FAMEs are unsaturated with double bonds in the alkyl chains. As the number of double bonds increases (more unsaturation), the EI measurements tend to lack molecular ions. In this work, we measured a standard sample containing multiple FAMEs using EI and FI to detect their molecular ions. The resulting data was further examined by using msFineAnalysis to produce an integrated report for these compounds in which the library database search was combined with the molecular ion exact mass analysis to produce a qualitative identification of these compounds.

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.
    © Copyright 2026 by JEOL USA, Inc.