Analytical Instrument Documents

Integrated Analysis of Coffee Aroma by using a Headspace GC-HRMS - MSTips 280

Electron ionization (EI) is a hard ionization method that is commonly used with gas chromatography mass spectrometry (GC-MS). The mass spectral fragmentation patterns produced by EI are used for library database searches to identify compounds. Conversely, soft ionization methods like field ionization (FI) tend to produce clear molecular ions with minimal fragmentation. When high-resolution MS is used with these ionization techniques, the accurate masses for the fragment ions produced by EI and the molecular ions produced by soft ionization provide an additional dimension of information for the analytes. Combining the exact mass information with the results of conventional library search can enhance the accuracy of identification compared to the use of library search alone.  In this work, we introduce the msFineAnalysis software and use it to automatically combine data acquired by GC/EI and GC/soft ionization for the qualitative analysis of coffee headspace.

Integrated Analysis of an Acrylic Resin using msFineAnalysis v2 - MSTips 300

In 2018, msFineAnalysis Ver.1 software was released in which data acquired by EI, soft ionization, and accurate mass measurements were automatically integrated to generate a qualitative report for samples measured by these techniques with GC-MS. Recently, msFineAnalysis Ver.2 was introduced as an enhanced version with additional features. In this work, we will describe the changes in Ver.2, which now includes chromatographic deconvolution, and present applications using the new features.

Analyzing a Specific Component using Group Analysis of msFineAnalysis Ver. 2 - MSTips 303

In 2018, we announced the msFineAnalysis software which was designed to automatically integrate two types of data acquired by EI and soft ionization. Recently, we developed msFineAnalysis Version 2, an enhanced version with additional features. msFineAnalysis Version 2 incorporates two new features: Chromatographic Deconvolution and Group Analysis. In this work, we use the group analysis capabilities of the software to evaluate the pyrolysis GC-MS results for a vinyl acetate resin.

GC-TOFMS Application: Natural Polymer Analysis by using Pyrolysis-GCxGC-MS -

A Japanese lacquer film called "Urushi" is a natural polymer that has been used as a paint and adhesive for living-wares and craft-wares for approximately 8,000 years. "Urushi" has a complex structure that researchers are trying to understand using pyrolysis-gas chromatograph/mass spectrometer (Py/GC/MS) system. Recently, we developed a new gas chromatograph/high resolution time-of-flight mass spectrometer (GC/HR-TOFMS) system that can be used for comprehensive two-dimensional GC (GCxGC) measurements. Additionally, we have developed a unique combination electron ionization/photoionization (EI/PI) ion source that can be used with this GC/HR-TOFMS system. In this work, we measured "Urushi" samples using this unique Py/GCxGC/HR-TOFMS system in combination with our new combination EI/PI ion source.

Visualizing fragmentation channels of polyethylene oxide with different end groups using S3000 - TOF-TOF - MSTips - 279

Tandem mass spectrometry is a powerful tool for polymer characterization. It can obtain information about polymer end groups, repeating structures (linear, cyclic, or branched), and copolymerization. High-energy collision–induced dissociation (HE-CID) is a fragmentation method that is available only in tandem time-of-flight mass spectrometry (TOF–TOF). The informative fragmentation channels, which are difficult to observe with commonly used low-energy CID, are often observable in HE-CID spectra. In MSTips 270, we proposed a method to visualize this abundant structural information and enable intuitive analysis using the “Remainders of KM” (RKM) plot method. In this report, we applied the method to analyze polyethylene oxide (PEO) with different end groups.

Apps Note Synthetic Polymer Structure PMMA

The JMS-S3000 “SpiralTOF™” is a MALDI-TOFMS that incorporates an innovative SpiralTOF ion optics system. This system is available with a TOF-TOF option that can acquire high-energy collision-induced dissociation (CID) product ion spectra for monoisotopically selected precursor ions. In this work, we analyzed Poly Methyl Methacrylate (PMMA) shown in Fig. 1 by using the JMS-S3000 SpiralTOF with the TOF-TOF option. The resulting high-energy CID data was then processed using the Polymerix™ (Sierra Analytics, Inc., http://massspec. com/) analysis software.

Structure analysis of a polymer additive using HE-CID MS acquired S3000 TOF-TOF - MSTips - 254

Various kinds of additives are used in a polymer, such as an antioxidant, a light stabilizer, and an ultraviolet absorber. Because a polymer’s properties depend on the additives in the raw material, it is important to understand these additives. Matrix-assistance laser desorption/ ionization time-of-flight mass spectrometer (MALDI-TOFMS) JMS-S3000 SpiralTOF™ is widely used in polymer analysis. High-energy collision–induced dissociation (HE-CID) measurement with the TOF-TOF option is also useful in analyzing the structures of additives. SpiralTOF™ can achieve a high precursor ion selection with a revolution of 17 m. Fragmentation derived from HE-CID can be observed only due to the ions from post-source decay (PSD), these fragment ions can be eliminated by the four electrostatic sectors that constitute the spiral trajectory. In this Applications Note, we report on polymer structural analysis by compare fragmentation patterns in the product ion spectra of IRGANOX 1076 M+・ and [M+Na]+.

Apps Note Analysis of Tristearin

The JMS-S3000 SpiralTOF™ is a MALDI-TOF MS that uses an innovative spiral ion optical system to achieve the highest resolution currently available for a MALDI instrument. Additionally, this system can be equipped with a TOF-TOF option that can acquire high-energy collisioninduced dissociation (HE-CID) product ion spectra for monoisotopically selected precursor ions. The resulting HE-CID product ion spectra provide detailed structural information about compounds like triglycerides by means of charge-remote fragmentation (CRF).1 Tristearin is a triglyceride found in fats that consists of three stearic acid moieties (Fig. 1). In this work, we report the structural analysis of tristearin by using the HE-CID capabilities of the SpiralTOF-TOF.

Apps Note Analysis of Triolein

The JMS-S3000 “SpiralTOF™” is a MALDI-TOF MS that uses an innovative spiral ion optical system to achieve the highest resolution currently available for a MALDI instrument. Additionally, this system can be equipped with a TOF-TOF option that can acquire high-energy collisioninduced dissociation (HE-CID) product ion spectra for monoisotopically selected precursor ions. The resulting HE-CID product ion spectra provide detailed structural information about compounds like triglycerides by means of charge-remote fragmentation (CRF). In this work, we report the structural analysis of triolein, a triglyceride that contains 3 oleic acid moieties (Fig. 1), by using HE-CID capabilities of the SpiralTOF-TOF.

Structural analysis of melatonin & related compounds using S3000 - TOF-TOF - MSTips - 256

The JMS-S3000 SpiralTOF™, which has a JEOL-patented spiral orbital ion optical system, has a long-flight distance of 17 m and can achieve high-mass resolution. In addition, the electrostatic sectors that constitute the ion optical system can exclude PSD ions, making it possible to acquire a mass spectrum that is less affected by background ions. These features enable accurate mass measurement even in LMW regions[1].

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.
    © Copyright 2026 by JEOL USA, Inc.
    Terms of Use
    |
    Privacy Policy
    |
    Cookie Preferences