Analytical Instrument Documents

Apps Note Molecular Weight Peptide

The JMS-S3000 SpiralTOF™ is a MALDI-TOF MS that uses an innovative spiral ion optics system to achieve the highest resolution currently available for a MALDI instrument. Additionally, the JMS-S3000 is available with a TOF-TOF option that acquires high-energy collision-induced dissociation (CID) product-ion spectra for monoisotopically selected precursor ions. In this work, we analyzed a high molecular weight peptide by using the JMS-S3000 SpiralTOF with the TOF-TOF option.

Remainders of KM plot for polymers-HECID - S3000 TOF-TOF - MSTips - 270

Tandem mass spectrometry of polymer ions provides valuable information about the nature of individual end-groups, chain architecture (linear / cyclic / branched) and copolymeric microstructure. Using matrix-assisted laser desorption ionization (MALDI) with high energy collision-induced dissociation (HE-CID) tandem time-of-flight analysis (TOF/TOF) can be advantageous for MS/MS polymer analysis. However, the interpretation of the resulting mass spectrum may not be obvious when a number of ion series with low intensity signals are present. In this work, a “remainders of Kendrick mass” (RKM) analysis is used as a rapid post-acquisition data processing tool for TOF/TOF mass spectra in order to visualize and filter the ion series instantly via intuitive point alignments.

Apps Note Small Molecule High Energy CID

The JMS-S3000 SpiralTOF™ is a MALDI-TOF MS that uses an innovative spiral ion optics system to achieve the highest resolution currently available for a MALDI instrument. As a result, small organic molecules can be analyzed on this system with minimal interferences from the matrix peaks. Additionally, the JMS-S3000 is available with a TOF-TOF option that can acquire highenergy collision-induced dissociation (CID) product ion spectra for monoisotopically selected precursor ions. In this work, we analyzed several small organic molecules by using the JMS-S3000 with the TOF-TOF option.

Apps Note Compare 4sector tandem

The JMS-3000 SpiralTOF™ has an optional TOF-TOF mode that features monoisotopic precursor ion selectivity, elimination of post source decay (PSD) ions, and high energy collision induced dissociation (CID). The JMS-700T MStation four-sector tandem double focusing mass spectrometer, although featuring a different analyzer and ionization techniques, has similar capabilities that have been previously used for a wide variety of applications including the structural analysis of complex biological molecules. In this work, we compare the SpiralTOF-TOF with the MStation four sector tandem double focusing mass spectrometer using the same sample for MS/MS analysis.

Analysis of organic compounds on an acrylic plate using S3000 - MSTips - 2512

Industrial materials are often evaluated by surface analysis instruments that provide information on surface elements, bonding states, and functional groups. However, there are limited options for surface analysis techniques that provide molecular weight and molecular structure information for organic compounds present on surfaces. Matrix Assisted Laser Desorption Ionization - Time of Flight Mass Spectrometry (MALDI-TOFMS) is a soft ionization technique that can be used to analyze surfaces in order to estimate elemental compositions with accurate mass measurements, obtain structural information by using MS/MS, and map surface compounds by using MS imaging. MALDI-TOFMS uses a high voltage on the target plate to accelerate the ions into the TOFMS analyzer. Therefore, the target plates are conductive and are typically made of stainless steel. MALDI imaging mass spectrometry is widely used for analyzing organic substances on frozen tissue sections. In this case, a frozen tissue section with a thickness of about 10 μm is placed on a conductive glass slide coated with an indium tin oxide (ITO) film. However, for the analysis of industrial products, the target organic compounds are on nonconductive substrates such as resins with millimeter thicknesses. MALDI-TOFMS surface measurements using nonconductive substrates lead to a reduction in mass resolution and a significant decrease in ion intensity due to surface charging. This problem can be solved by pretreating the surface with gold vapor deposition in order to change it from nonconductive to conductive. This method was previously shown to work well in MSTips No. 204 in which the gold vapor deposition method was applied to the MALDI-MS imaging analysis of inks on paper. In this report, we used gold vapor deposition to look at samples on the surface of a 1 mm thick acrylic plate.

Remainders of KM plot for polymers-HMW - S3000 - MSTips - 269

Mass Spectrometry (MS) with soft ionization such as matrix-assisted laser desorption ionization (MALDI) allows the compositional analysis of polymers (repeating units, chain terminations) of low dispersity. Combining a size exclusion chromatography (SEC) fractionation with a high-resolution MALDI SpiralTOF™ MS analysis enables the evaluation of the composition of polydisperse polymeric samples over a broad mass range (high-resolution/high-accuracy mass measurements in the low mass range < 4 kDa, isotopic resolution in higher mass range < 30kDa). However, as the resolution gets higher, more peaks are detected in the mass spectrum for each fraction, making the interpretation of the mass spectral data the rate-limiting step for the whole analytical procedure. In this work, a “remainders of Kendrick mass” (RKM) analysis is used as a rapid post-acquisition data processing tool that uses visual maps from combined low/high-accuracy and low/high mass range data.

Apps Note Polystyrene

Polystyrene (PS)1000 and 2400 were measured using the JMS-S3000 SpiralTOF. The [M+H]+ peaks of PS with the basic monomer units of 104u (Fig.1) were observed for each sample. The mass spectrum of PS1000 and an expanded view around m/z 1000 are shown in Fig. 2. The resolving power at m/z 1101 was approximately 50,000 (FWHM). The mass difference between 8, 9 and 10-mers showed a very good match with the theoretical mass number (104.0626) calculated from the elemental composition of the repeating unit (C8H8). The mass spectrum of PS2400 and the expanded view of the isotopic pattern of 23-mer are shown in Fig 3. The observed isotopic pattern of the 23-mer is in very good agreement with the simulated isotopic distribution (R 60,000).

Apps Note Polymethyl methacrylate

Polymethyl methacrylate (PMMA) 4000 was measured by using the JMS-S3000 SpiralTOF. The [M+H]+ peaks for PMMA with the basic monomer units of 100u (Fig.1) were observed for this sample. The full PMMA mass spectrum and an expanded view around m/z 4000 are shown in Fig. 2(a) and (b), respectively. The resolving power at m/z 4,000 was approximately 45,000 (FWHM). Also, the mass differences between the 39, 40, and 41- mers had a very good match with the theoretical mass number (100.0524) of the PMMA repeat unit (C5H8O2). A comparison between the 40-mer’s observed and simulated isotopic patterns is shown in Fig. 2(c). The observed isotopic pattern is in very good agreement with the calculated isotopic distribution.

Apps Note Polyethylene Glycol

Polyethylene glycol (PEG) 1000 and 8000 were measured by using the JMS-S3000 SpiralTOF. The [M+H]+ peaks for PEG with the basic monomer units of 44u (Fig. 1) were observed for each sample. The mass spectrum for PEG1000 and an expanded view around m/z 1,000 are shown in Fig. 2. The resolving power at m/z 1009 is approximately 60,000 (FWHM). The mass difference between the 21, 22 and 23-mers showed very good agreement with the theoretical mass of the PEG monomer. The full mass spectrum for PEG8000 is shown in Fig. 3(a). The comparison between the observed and simulated isotopic pattern (R 35,000) for the 226mer are shown in Fig. 3(b). The observed isotopic pattern is in very good agreement with the calculated isotopic distribution.

Fraction base-KMD plots for a high-MW-copolyester following its on-plate alkaline degradation - S3000 - MSTips - 284

High molecular weight polymers are often MS-silent due to their inherent high dispersity (ĐM) or detected in the high mass range with low resolving power. High-resolution mass spectrometry (HRMS) is indeed limited to the low mass range (< 3000 Da) for an unambiguous evaluation of the nature of repeating units and/or end-groups or the isolation of isobaric compounds. An “on-plate” alkaline degradation has thus been developed as a sample pre-treatment on the MALDI target with tenths of ng of polymer to cut long industrial polyester chains into short oligomers amenable to MALDI-HRMS [1]. The complexity of the associated mass spectra can be greatly reduced with the appropriate resolution-enhanced Kendrick mass defect (KMD) analysis using the “fraction base” option of msRepeatFinder to produce compositional maps.

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.