Analytical Instrument Documents

Semi-quantitative Analysis of Low-molecular-weight_Cyclic_Siloxane_in_Silicone_Rubber-PyGCMS-MSTips_247

Silicone rubber is made from low-molecular-weight (LMW) cyclic siloxane. Most LMW cyclic siloxane is used up during the polymerization process, and the residual cyclic siloxane is removed by subsequent heating and depressurization steps. Generally, the residual level of cyclic siloxane is <3% in silicone rubber, but in the field of electronic equipment manufacturing, residual cyclic siloxane levels must be < 1% in order to avoid contact failure of relays, connectors, etc. due to gases evolved by LMW cyclic siloxane. In this application note, we show semi-quantitative analysis results of LMW cyclic siloxane in silicone rubber that was analyzed using the EGA/PY-3030D pyrolyzer (Py) (Frontier Laboratories, Ltd.) and the gas chromatography–quadrupole mass-spectrometer (GC/QMS) instrument JMS-Q1500GC (JEOL).

Qualitative Analysis of Calcium Oxalate Using TG-MS System

A thermogravimetry/differential thermal analysis (TG/DTA) system is used to measure weight changes and relative temperatures of samples under programmed heat conditions. A system combining TG/DTA with mass spectrometry (MS) is called a TG-MS system, and is considered one of the best qualitative and quantitative analysis systems for inorganic materials because it can measure sample conditions, evolved gas species, and gas volume simultaneously. In this application note, we introduce the basic application of analyzing calcium oxalate using the TG-MS “STA2500 Regulus” system (NETZSCH) and the GC/QMS “JMS-Q1500GC” system (JEOL).

Phthalates Impurity Analysis of PVC Resin Made with Alternative Plasticizers

The phthalates used as plasticizers in polymer resins are endocrine-disrupting substances that are a risk to human health. Therefore, the use of phthalates is limited by various government agencies. In the field of electrical equipment manufacturing, diisobutyl phthalate (DIBP), dibutyl phthalate (DBP), butyl benzyl phthalate (BBP), and di-2-ethylhexyl phthalate (DEHP) are regulated by the European Union’s Restriction of Hazardous Substances (RoHS) Directive. The use of DBP, BBP, DEHP, di-n-octyl phthalate (DNOP), diisononyl phthalate (DINP), and diisodecyl phthalate (DIDP) in toys and baby care products is regulated in Europe, the United States, China, and Japan. Phthalates subject to regulation are being replaced with alternative substances. However, it is known that phthalates tend to contaminate the manufacturing process and storage areas. Some alternative materials (e.g., tris-2-ethylhexyl trimellitate [TOTM]) may contain regulated components (e.g., DEHP) as impurities. In this report, PVC cables for commercial products using alternative substances as plasticizers were analyzed by the pyrolysis/thermal desorption–gas chromatography–mass spectrometry (Py/TD-GC-MS) method described in IEC 62321-8: 2017 [1]. Any phthalates discovered were quantified, and spectral information was collected for other detected compounds.

Analyzing Photodegraded Styrofoam by Using Py/GC/MS with a Combination EI/PI Ion Source

Electron ionization (EI) is the most commonly used ionization technique in gas chromatography–mass spectrometry (GC-MS). This hard ionization technique (70eV) provides excessive energy to organic compounds that results in highly reproducible fragment ions with relatively high ion intensities. As a result, EI databases have been created that help with identifying the compounds of interest. Despite this ability to do database searches, some compounds (alkanes, alcohols, etc.) do not produce abundant molecular ions, thus making it difficult to differentiate similar compounds from each other. By contrast, photoionization (PI) is a soft ionization technique that uses a vacuum ultraviolet (VUV) light source to provide ionization energies in the range of 8–10eV. This range is optimal for the soft ionization of common organic compounds which have an ionization energy in the range of 8–11eV. This low ionization energy results in stronger molecular ion signals and less fragmentation than for EI. Combining an EI library search with PI molecular ion information can improve the accuracy of the qualitative analysis results. In this work, we report on the qualitative analysis of styrene foam (Styrofoam) before and after photodegradation, using pyrolysis (Py)-GC/MS with an EI/PI combination ion source.

Comparative analysis of mechanical pencil lead by TG-MS

Thermogravimetry (TG) is used to measure weight changes of samples under programmed heat conditions. A system combining thermogravimetry/differential thermal analysis (TG/DTA) with mass spectrometry (MS) is called a TG-MS system, and can be used for both qualitative and quantitative mass spectral analysis of evolved gas from the TG furnace. The TG-MS technique can also be used to analyze the thermal-decomposition process. This application note shows an example of comparative analysis of mechanical-pencil leads of different performances, grades, and manufacturers. These leads are made by baking a mixture of graphite and resin, and then dipping it in oil for hardness and smoothness. Since the resin is carbonized and baked out, the lead is composed of only carbon and oil. In this application note, we show TG-MS analysis results for these mechanical-pencil leads using a “STA2500 Regulus” system (NETZSCH) and a gas chromatography–quadrupole mass spectrometry (GC/QMS) “JMS-Q1500GC” system (JEOL).

Acquisitions of Molecular-weight Information Using Soft-ionization Techniques (PI and CI)

Electron ionization (EI), a hard-ionization technique that generates many fragment ions, is the most widely used ionization technique in gas chromatography–mass spectrometry (GC-MS). Since EI mass spectra have good reproducibility, qualitative analysis is possible by comparing an EI mass spectrum of a sample with that of the known compound recorded in the database. However, sometimes EI mass spectra lack molecular ions, which are of key importance to molecular-weight (MW) determination and correct compound assignment. Soft ionization is a useful way to determine MW. The JEOL JMS-Q1500GC offers two soft-ionization techniques: chemical ionization (CI) and photoionization (PI). In this application note, the MW information of diethyl phthalate and n-tetradecane were estimated from measurement results using both of these soft-ionization techniques.

Type Analysis of Micro Crystalline Wax (Petroleum Wax) by Using Field Desorption (FD) Ionization

Petroleum waxes are a class of hydrocarbons that are solid at room temperature and are classified by the Japan Industrial Standards (JIS K2235) into 3 types: paraffin wax, micro crystalline wax, and petrolatum. A typical micro crystalline wax contains hydrocarbons having a carbon number of 30 to 60 and molecular weights between 500 and 800. In addition to paraffins, these waxes also include large quantities of isoparaffins and cycloparaffins. Field desorption (FD) is an ionization technique that utilizes the tunneling effect of electrons in the presence of a high electric field. The sample is applied directly onto an FD emitter filament, and then an electric current is applied to the filament to produce a high electric field across the emitter surface (including the whisker tips) to desorb and ionize the samples. As a soft ionization technique that minimizes fragmentation and produces molecular ions, FD has been previously used for analyzing refractory compounds and high molecular weight polymers. In this work we ionized a micro crystalline wax by using a JMS-T100GC AccuTOF-GC with FD ionization to do a sample type analysis that was based on the mass and intensity of the resulting ions.

ZW Exact Mass Measurement

Recently, JEOL introduced the AccuTOF-GC, an innovative GC/time-of-flight mass spectrometer (TOF MS) that is capable of both high data acquisition rates and easy exact mass measurements. The exact mass measurements can then be used to generate lists of possible elemental compositions, which is a powerful tool for identifying unknown compounds. Additionally, this information can be combined with the fragmentation information to help confirm the identity an unknown compound. In this work, the AccuTOF-GC system was used to identify an unknown compound in a liquid crystal extract.

Rapid Analysis Using Deactivated Fused Silica Tubing(a.k.a. “Guard Column”) as the Sample Inlet (2)

Average molecular weight is an important reference for evaluating samples with molecular weight distributions, such as crude oils, which are complex mixtures, or synthetic polymers. Almost all of the ions observed in field desorption (FD) and field ionization (FI) mass spectra are molecular ions since they are both soft ionization methods. The average molecular weight of a sample can be calculated directly from the masses (or “m/z”) and intensities of all of the ions observed by FD or FI. By applying group-type analysis, the components can be classified into types based on their functional groups and/or unsaturations. Average molecular weight, polydispersity index, or relative abundance of each type can be obtained.

Rapid Analysis Using Deactivated Fused Silica Tubing(a.k.a. “Guard Column”) as the Sample Inlet (1)

Average molecular weight is an important reference for evaluating samples with molecular weight distributions, such as crude oils, which are complex mixtures, or synthetic polymers. Almost all of the ions observed in field desorption (FD) and field ionization (FI) mass spectra are molecular ions because they are both soft ionization methods. As a result, the average molecular weight of a sample can be calculated directly from the masses (or “m/z”) and intensities for all of the ions observed in the FD or FI mass spectra. By applying group-type analysis, the components can be classified into types based on their functional groups and/or unsaturations. Average molecular weight, polydispersity index, or relative abundance of each type can be obtained.

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.