AccuTOF™ LC-plus 4G Time-of-Flight Mass Spectrometer

Probe Status Connector

Changing probes has never been as easy--or as worry-free--as with JEOL's probe status connector.

Autotuning

With the JEOL AutoTune 5mm NMR Probe and JEOL standard broadband NMR capability, all multi-nuclear spectra from 1H, 19F, 31P to 15N are available under computer control.

Variable Temperature

For above ambient temperature operation, simply set the desired temperature in the software. For below-ambient temperature operation, just two simple connections are required. Running VT analyses does not have to be hard!

Automated No-D NMR

Now there is a fast, easy way for the synthetic organic or process chemist to run NMR experiments without using expensive deuterated solvents. JEOL automates the collection of “No-D” NMR data using the advanced Delta™ automation software and easy selective 1H gradient shimming.

NMR Probe Key Product Features

Probe Type Probe Series Auto-tune Pulsed Field
Gradients
Tuning Ranges
Normal Geometry TH5, TH3
C5FH
T10
T10L
yes, no
no
yes
no
yes
yes
yes
no
1H, 19F and 31P-15N
13C and 1H, 19F
31P-15N and 1H
15N-103Rh and 1H
Inverse Geometry H5X, H3X
HCN
yes, no
yes
yes
yes
1H, 19F and 31P-15N
1H and 13C and 15N
    JEOL USA, Inc.
    11 Dearborn Road
    Peabody, MA 01960
    © Copyright 2022 by JEOL USA, Inc.
    Probe TypeProbe SeriesAuto-tunePulsed Field
    Gradients
    Tuning Ranges
    Normal GeometryTH5, TH3
    C5FH
    T10
    T10L
    yes, no
    no
    yes
    no
    yes
    yes
    yes
    no
    1H, 19F and 31P-15N
    13C and 1H, 19F
    31P-15N and 1H
    15N-103Rh and 1H
    Inverse GeometryH5X, H3X
    HCN
    yes, no
    yes
    yes
    yes
    1H, 19F and 31P-15N
    1H and 13C and 15N

    Probe Status Connector

    - Changing probes has never been as easy--or as worry-free--as with JEOL's probe status connector.

     

    Autotuning

    - With the JEOL AutoTune 5mm NMR Probe and JEOL standard broadband NMR capability, all multi-nuclear spectra from 1H, 19F, 31P to 15N are available under computer control.

     

    Variable Temperature

    - For above ambient temperature operation, simply set the desired temperature in the software. For below-ambient temperature operation, just two simple connections are required. Running VT analyses does not have to be hard!

     

    Automated No-D NMR

    - Now there is a fast, easy way for the synthetic organic or process chemist to run NMR experiments without using expensive deuterated solvents. JEOL automates the collection of “No-D” NMR data using the advanced Delta™ automation software and easy selective 1H gradient shimming.