Analytical Instrument Documents

JEOL Resources

rss

Documentation in support of your JEOL product.

Utilizing msFineAnalysis AI to Verify an Organic Synthetic Compound Structure Based on the Data Acquired by Gas Chromatography-High Resolution Mass Spectrometry and Nuclear Magnetic Resonance - Direct MS Probe Measurement
Utilizing msFineAnalysis AI to Verify an Organic Synthetic Compound Structure Based on the Data Acquired by Gas Chromatography-High Resolution Mass Spectrometry and Nuclear Magnetic Resonance - Direct MS Probe Measurement
MSTips No. 475

General

Gas chromatography-high resolution mass spectrometry (GC-HRMS) combined with nuclear magnetic resonance spectroscopy (NMR) is widely used for identifying chemical compositions and structures of organic synthetic compounds.

If a target sample is a high boiling point compound, which does not pass through GC, direct MS measurement is more suitable than GC-MS. The JMS-T2000GC, a GC-HRMS system, supports three different direct MS probes: 1) DIP (Direct Insert Probe) to heat a gas capillary containing a sample; 2) DEP (Direct Exposure Probe) with a filament; and 3) FDP (Field Desorption Probe) designed for field desorption, a soft ionization method. msFineAnalysis AI, designed to predict chemical compositions and formula, is effective in analyzing results acquired by direct MS as well as GC-MS, to determine desired NMR measurement methods and analyze the resulting NMR data.

JEOL’s ROYALPROBETM HFX, an accessory for the JNM-ECZ600R NMR system, is capable of tuning on the HF side (1H,19F) for single and double resonance, allowing the operator to select one desired for the experiment. Combined with the LF side (13C, etc.), the probe supports simultaneous tuning for triple resonance, rendering itself as a powerful tool to determine chemical structures of organic synthetic compounds made of C, H, and F.

In this work, we examined a high boiling point compound in a JMS-T2000GC using a DEP, EI (DEI: Desorption Electron Ionization), FD (Field Desorption), and msFineAnalysis AI, and analyzed the resulting data in a JNM-ECZ600R with ROYALPROBETM HFX to determine its chemical composition and structure.

Attached Files

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.