Analytical Instrument Documents

Simultaneous analysis of pesticide residues by GC-MS/MS method using Hydrogen carrier gas

Switching to an alternative carrier gas requires a review of the previously used measurement conditions. This report introduces an example of using hydrogen as a carrier gas for the simultaneous analysis of pesticide residues in food by GC-MS/MS method.

Analysis of Simazine and Thiobencarb by GC-MS method using nitrogen carrier gas

In this report, simazine and thiobencarb, which are pesticides subject to environmental standards related to water pollution, were measured using N₂ carrier gas, and the difference in sensitivity from He, linearity of the calibration curve, and reproducibility during continuous measurement were confirmed.

JMS-T2000GC AccuTOF™ GC-Alpha Sensitivity in nitrogen carrier gas ③ - CI ion source

We have checked the influences of nitrogen carrier gas on JMS-T2000 GC AccuTOF ™ GC-Alpha, and report on MS Tips No. 374-376. This report shows the results of the CI (Chemical Ionization) ion source.

JMS-T2000GC AccuTOF™ GC-Alpha Sensitivity in nitrogen carrier gas ② - EI / FI ion source

We have checked the influences of nitrogen carrier gas on JMS-T2000 GC AccuTOF™ GC-Alpha, and report on MSTips No. 374-376. This report shows the results of the EI (Electron Ionization) / FI (Field Ionization)combination ion source, which is one of the characteristic multi-ionization ion sources of JMS-T2000 GC AccuTOF™ GC-Alpha.

JMS-T2000GC AccuTOF™ GC-Alpha Sensitivity in nitrogen carrier gas ① - EI / PI ion source

We have checked the influences of nitrogen carrier gas on JMS-T2000 GC AccuTOF™ GC-Alpha, and report on MS Tips No. 374-376. This report shows the results of the EI (Electron Ionization) / PI (Photo Ionization) combination ion source, which is one of the characteristic multi-ionization ion sources of JMS-T2000 GC AccuTOF™ GC-Alpha.

High mass-resolution MS imaging using JMS-S3000

In this report, we report the statistical analysis of high-mass resolution MALDI-MSI data of various lipids in biological samples.

Structural analysis of a small molecule using JMS-S3000

SpiralTOF™-plus 2.0 with TOF-TOF option can achieve high precursor ion selectivity due to the long flight path of the spiral ion optics used in the 1st TOFMS. In this application note, we report the structural elucidation of a photodegradation product of reserpine as an example of structural analysis of a component close to a possible interference in mass by MS/MS measurement using the SpiralTOF™-plus 2.0 with TOF-TOF option.

Analysis of oligonucleotides using JMS-S3000

Molecular weight confirmation of synthesized oligonucleotides is important for the quality control of pharmaceuticals. In this report, we used the synthesized oligonucleotide (Table 1) as a sample and measured it with a MALDI-TOFMS.

Differential analysis of coffee aroma compounds using HS GC-QMS and msFineAnalysis iQ

Coffee aroma contains a very large number of components. Therefore, a large number of peaks are observed in TIC chromatogram, and it takes a long time to identify the components of each peak and to analyze differences between samples. In this report, we present the results of differential and integrated analyses performed on coffee aroma components using msFineAnalysis iQ.

Integrated qualitative analysis of fatty acid methyl esters (FAMEs) by msFineAnalysis iQ

We report the results of the integrated qualitative analysis combining library database search and molecular ion confirmation when performing msFineAnalysis iQ.

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.