Analytical Instrument Documents

Analyzing Photodegraded Styrofoam by Using Py/GC/MS with a Combination EI/PI Ion Source

Electron ionization (EI) is the most commonly used ionization technique in gas chromatography–mass spectrometry (GC-MS). This hard ionization technique (70eV) provides excessive energy to organic compounds that results in highly reproducible fragment ions with relatively high ion intensities. As a result, EI databases have been created that help with identifying the compounds of interest. Despite this ability to do database searches, some compounds (alkanes, alcohols, etc.) do not produce abundant molecular ions, thus making it difficult to differentiate similar compounds from each other. By contrast, photoionization (PI) is a soft ionization technique that uses a vacuum ultraviolet (VUV) light source to provide ionization energies in the range of 8–10eV. This range is optimal for the soft ionization of common organic compounds which have an ionization energy in the range of 8–11eV. This low ionization energy results in stronger molecular ion signals and less fragmentation than for EI. Combining an EI library search with PI molecular ion information can improve the accuracy of the qualitative analysis results. In this work, we report on the qualitative analysis of styrene foam (Styrofoam) before and after photodegradation, using pyrolysis (Py)-GC/MS with an EI/PI combination ion source.

Comparative analysis of mechanical pencil lead by TG-MS

Thermogravimetry (TG) is used to measure weight changes of samples under programmed heat conditions. A system combining thermogravimetry/differential thermal analysis (TG/DTA) with mass spectrometry (MS) is called a TG-MS system, and can be used for both qualitative and quantitative mass spectral analysis of evolved gas from the TG furnace. The TG-MS technique can also be used to analyze the thermal-decomposition process. This application note shows an example of comparative analysis of mechanical-pencil leads of different performances, grades, and manufacturers. These leads are made by baking a mixture of graphite and resin, and then dipping it in oil for hardness and smoothness. Since the resin is carbonized and baked out, the lead is composed of only carbon and oil. In this application note, we show TG-MS analysis results for these mechanical-pencil leads using a “STA2500 Regulus” system (NETZSCH) and a gas chromatography–quadrupole mass spectrometry (GC/QMS) “JMS-Q1500GC” system (JEOL).

Acquisitions of Molecular-weight Information Using Soft-ionization Techniques (PI and CI)

Electron ionization (EI), a hard-ionization technique that generates many fragment ions, is the most widely used ionization technique in gas chromatography–mass spectrometry (GC-MS). Since EI mass spectra have good reproducibility, qualitative analysis is possible by comparing an EI mass spectrum of a sample with that of the known compound recorded in the database. However, sometimes EI mass spectra lack molecular ions, which are of key importance to molecular-weight (MW) determination and correct compound assignment. Soft ionization is a useful way to determine MW. The JEOL JMS-Q1500GC offers two soft-ionization techniques: chemical ionization (CI) and photoionization (PI). In this application note, the MW information of diethyl phthalate and n-tetradecane were estimated from measurement results using both of these soft-ionization techniques.

Using Volcano Plots to Compare Vinyl Acetate Resin Samples Measured by Pyrolysis GC-MS

Advances in mass spectrometry are enabling analysis of micro samples and unknown components that were not observable before. As the volume of information acquired from mass spectrometry increases, researchers are calling for simple techniques to analyze the numerous components observed, and as a result, there is a rise in demand for comprehensive analytical techniques including multiple classification analysis. In this work, we analyzed 2 samples in a high resolution GC-TOFMS, using EI, the most widely used ionization technique for GC-MS, and compared the data acquired by using a comprehensive analytical technique.

Type Analysis of Micro Crystalline Wax (Petroleum Wax) by Using Field Desorption (FD) Ionization

Petroleum waxes are a class of hydrocarbons that are solid at room temperature and are classified by the Japan Industrial Standards (JIS K2235) into 3 types: paraffin wax, micro crystalline wax, and petrolatum. A typical micro crystalline wax contains hydrocarbons having a carbon number of 30 to 60 and molecular weights between 500 and 800. In addition to paraffins, these waxes also include large quantities of isoparaffins and cycloparaffins. Field desorption (FD) is an ionization technique that utilizes the tunneling effect of electrons in the presence of a high electric field. The sample is applied directly onto an FD emitter filament, and then an electric current is applied to the filament to produce a high electric field across the emitter surface (including the whisker tips) to desorb and ionize the samples. As a soft ionization technique that minimizes fragmentation and produces molecular ions, FD has been previously used for analyzing refractory compounds and high molecular weight polymers. In this work we ionized a micro crystalline wax by using a JMS-T100GC AccuTOF-GC with FD ionization to do a sample type analysis that was based on the mass and intensity of the resulting ions.

Antioxidant Additive

JEOL has developed a unique EI/FI/FD combination ion source for the “AccuTOF GCv 4G”, a high- resolution GC-time-of-flight (TOF) MS system. This unique ion source provides the capabilities of GC/EI, GC/FI and FD measurements without having to break vacuum in order to switch between each ionization mode. Additionally, this combination is particularly powerful in that it provides library searchable fragmentation information by using EI and high mass accuracy molecular ion information by using FI and FD. In this work, we measured an antioxidant additive by using each ionization mode available on the AccuTOF GCv 4G combination ion source (EI/FI/FD).

ZW Exact Mass Measurement

Recently, JEOL introduced the AccuTOF-GC, an innovative GC/time-of-flight mass spectrometer (TOF MS) that is capable of both high data acquisition rates and easy exact mass measurements. The exact mass measurements can then be used to generate lists of possible elemental compositions, which is a powerful tool for identifying unknown compounds. Additionally, this information can be combined with the fragmentation information to help confirm the identity an unknown compound. In this work, the AccuTOF-GC system was used to identify an unknown compound in a liquid crystal extract.

SPME-GCxGC/HRTOFMS Analysis of Tequila

The JEOL “AccuTOF GCv 4G” is a third generation GC/HRTOFMS system with high speed data acquisition capabilities of up to 50Hz which makes it well suited as the detector for comprehensive 2-dimensional GC (GCxGC) measurements. Along with the high speed data acquisition, this MS system also provides high mass resolution, accurate mass measurements, and high sensitivity, all simultaneously. Consequently, this GCxGC/HRTOFMS system is a powerful tool for the qualitative analysis of complicated samples. In this work, we measured commercially available tequila samples using GCxGC/HRTOFMS combined with solid-phase micro-extraction (SPME) preparation.

Rapid Analysis Using Deactivated Fused Silica Tubing(a.k.a. “Guard Column”) as the Sample Inlet (2)

Average molecular weight is an important reference for evaluating samples with molecular weight distributions, such as crude oils, which are complex mixtures, or synthetic polymers. Almost all of the ions observed in field desorption (FD) and field ionization (FI) mass spectra are molecular ions since they are both soft ionization methods. The average molecular weight of a sample can be calculated directly from the masses (or “m/z”) and intensities of all of the ions observed by FD or FI. By applying group-type analysis, the components can be classified into types based on their functional groups and/or unsaturations. Average molecular weight, polydispersity index, or relative abundance of each type can be obtained.

Rapid Analysis Using Deactivated Fused Silica Tubing(a.k.a. “Guard Column”) as the Sample Inlet (1)

Average molecular weight is an important reference for evaluating samples with molecular weight distributions, such as crude oils, which are complex mixtures, or synthetic polymers. Almost all of the ions observed in field desorption (FD) and field ionization (FI) mass spectra are molecular ions because they are both soft ionization methods. As a result, the average molecular weight of a sample can be calculated directly from the masses (or “m/z”) and intensities for all of the ions observed in the FD or FI mass spectra. By applying group-type analysis, the components can be classified into types based on their functional groups and/or unsaturations. Average molecular weight, polydispersity index, or relative abundance of each type can be obtained.

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.