JEOL CRYO ARM™ and inter-operability

Determining the near-atomic resolution structure of a biological macromolecule requires time on a high-end electron cryo-microscope. Depending on the local situation this could mean acquiring images of frozen-hydrated specimens on a JEOL CRYO ARM™ and/or another cryo microscope. To optimize inter-operability between different brands of cryo-microscopes, JEOL have investigated two related aspects: a) the reverse transfer, that is extracting frozen-hydrated specimens from one microscope to be transferred to another one, and b) the usability of a special cartridge designated as AG that are AutoGrid compatible.


Fig. 1: Images before (left) and after (right) a reverse transfer on a JEOL CRYO ARM™ 300.

Figure 1 shows results from the reverse transfer procedure. A pre-cooled transfer cup was used to ensure the specimens remain in the frozen-hydrated state. A minimal amount of transfer ice is present after the procedure but overall the specimen is in good condition.


Fig. 2: Cartridges compatible with AutoGrids (A) and retrieval of frozen- hydrated grids (B).

Figure 2 shows the cartridges that are critical for complete inter-operability between JEOL and other cryo- microscopes. Two are shown here, the AG-cartridge and the specimen-retrieval cartridge. The AG-cartridge is shown in Fig. 2A as a side-view (top), with the AutoGrid before insertion (bottom left) and after insertion, when it is ready for transfer into the CRYO ARM™ (bottom right). Fig. 2B shows the specimen retrieval cartridge recommended when frozen-hydrated specimens need to be transferred into another microscope.

Both cartridges employ a sliding cover to secure the grid in the cartridge. Fig. 3 shows data acquired after a short, 30- min acquisition run on a CRYO ARM™ 300 showing that the AG-cartridge reveals no detriment in collecting high resolution images.


Fig. 3: 3D reconstruction of apo-ferritin after 30 min data collection of sample inserted in an AG-compatible cartridge (A). FSC curve of the dataset comprised of 91k particle showing 2Å resolution (B).

Attached Files
Showing 0 Comment


Comments are closed.

Other Resources

  • Image Gallery
    View a selection of electron images
  • FAQs
    See answers from questions often asked about our SEM and Surface Analysis instruments
  • Links & Resources
    View our page of useful and interesting links to various electron microscopy resources
  • Videos
    View some product presentations of our instruments
  • SEM Theory and SEM Training
    Learn about basic theory, physical operation, and practical applications for SEM
    Basics of SEM
    Learn about the basics of scanning electron microscopy
    JEOLink Newsletter
    Several times a year, we publish and send out a newsletter to our customers. They can also be viewed here
    © Copyright 2024 by JEOL USA, Inc.
    Terms of Use
    |
    Privacy Policy
    |
    Cookie Preferences