Analytical Instrument Documents

JEOL Resources

rss

Documentation in support of your JEOL product.

Analysis of Musty Odor Compounds in Water by SPME-GC-MS/MS
Analysis of Musty Odor Compounds in Water by SPME-GC-MS/MS
MSTips No. 524

Musty odors (off-flavors) in water are primarily caused by 2-Methylisoborneol (2-MIB) and Geosmin produced by cyanobacteria. In addition, anisoles—formed through the microbial metabolism (methylation) of chlorophenols used in wood preservatives and pesticides—are also known contributors. Because these compounds cause unpleasant odors even at extremely low concentrations, precise monitoring is essential for water quality management. This report presents an example of the rapid, simultaneous analysis of these musty odor compounds using the SPME-GC-MS/MS method. Solid Phase Microextraction (SPME) is a technique in which a fine, polymer-coated fiber is exposed to the sample water (or its headspace) to adsorb and concentrate target components. We evaluated the detectability at a concentration of 1 ppt using standard samples, as well as the linearity of the calibration curves for quantification and the repeatability at the lower limit of quantification.

Attached Files

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.
    © Copyright 2026 by JEOL USA, Inc.
    Terms of Use
    |
    Privacy Policy
    |
    Cookie Preferences