Analytical Instrument Documents

Analysis of organic compounds on an acrylic plate using S3000

Industrial materials are often evaluated by surface analysis instruments that provide information on surface elements, bonding states, and functional groups. However, there are limited options for surface analysis techniques that provide molecular weight and molecular structure information for organic compounds present on surfaces. Matrix Assisted Laser Desorption Ionization - Time of Flight Mass Spectrometry (MALDI-TOFMS) is a soft ionization technique that can be used to analyze surfaces in order to estimate elemental compositions with accurate mass measurements, obtain structural information by using MS/MS, and map surface compounds by using MS imaging. MALDI-TOFMS uses a high voltage on the target plate to accelerate the ions into the TOFMS analyzer. Therefore, the target plates are conductive and are typically made of stainless steel. MALDI imaging mass spectrometry is widely used for analyzing organic substances on frozen tissue sections. In this case, a frozen tissue section with a thickness of about 10 μm is placed on a conductive glass slide coated with an indium tin oxide (ITO) film. However, for the analysis of industrial products, the target organic compounds are on nonconductive substrates such as resins with millimeter thicknesses. MALDI-TOFMS surface measurements using nonconductive substrates lead to a reduction in mass resolution and a significant decrease in ion intensity due to surface charging. This problem can be solved by pretreating the surface with gold vapor deposition in order to change it from nonconductive to conductive. This method was previously shown to work well in MSTips No. 204 in which the gold vapor deposition method was applied to the MALDI-MS imaging analysis of inks on paper. In this report, we used gold vapor deposition to look at samples on the surface of a 1 mm thick acrylic plate.

Analysis of low MW polyethylene with solvent-free method using S3000 - MSTips - 235

Matrix assisted laser desorption ionization (MALDI) time-flight mass spectrometer (TOFMS) is a powerful tool to identify the repeat units and end groups of polymers. The mass spectra of polymers can be easily interpreted because MALDI can generate singly-charged ions over a wide mass range. MALDI is a soft ionization method that uses "matrix" compounds and “cationization agents” to assist the ionization process of polymers. Typically, sample, matrix and cationization agent are dissolved in the same solvent. These solutions are pre-mixed and placed drop-wise on the target plate to make cocrystals (dried droplet method). However, this procedure cannot be applied to polymers that are insoluble or only slightly soluble. To solve this problem, solvent-free methods have been developed [1-4] for these situations. In this report, we analyzed low molecular weight polyethylene by using a solvent-free method and then using a high mass-resolution MALDI-TOFMS “SpiralTOF™” system for the analysis.

Analysis of EO-PO Random Copolymer by Using a Conventional HPLC and MALDI SpiralTOF MS

Ethylene oxide (EO) – propylene oxide (PO) copolymers have been used as components of various functional materials. Detailed analyses of them, however, still remain challenging. As it turns out, it is difficult to detect all of the components by using mass spectrometry alone without chromatographic separation due to ion suppression effects. In this work we analyzed an EO-PO random copolymer by using an LC – MALDI-SpiralTOF MS system, with the expectation of detecting more components as a result of reduced ion suppression effects.

MSI on mixed conductive non-conductive substrate using S3000 - MSTips - 288

In the industrial field, there is interest in measuring organic compounds on non-conductive substrates, such as resins a few millimeters thick. If the mass spectrum is obtained from the non-conductive surface with no pre-treatment, the mass resolution will be lower, and ultimately the ion intensity will decrease significantly due to the charge-up effect. This issue can be solved by providing conductivity to the non-conductive part via the gold deposition method.[1] In this report, MSI is performed using a permanent red marker on a substrate with a conductive part and a non-conductive part. Previously, ions could be observed only from the conductive part. Now, with the gold deposition method, they can be observed from both the conductive and the non-conductive parts, and they can be properly mapped.

Apps Note Drug Metabolism in Tissue

The JMS-S3000 SpiralTOF is a MALDI-TOFMS, which utilizes the JEOL patented spiral ion optics system. It has a 5-10 times longer flight path than the typical reflectron type MALDI-TOFMS. As a result, it can achieve high mass-resolution to separate peaks that have the same nominal mass but have different exact masses (isobaric separation). This feature is particularly effective for MALDI-Imaging for drug metabolism, which typically consist of relatively low molecular weight compounds which are often interfered with by matrix compounds and/or surface contaminants.

Apps Note MALDI Vision

Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MS Imaging) is a powerful tool for the biochemical analyses of surfaces. Previously, this technique has been used to determine the spatial distribution of hundreds of unknown compounds in thinly sliced tissue sections. The mass spectral images are generated by changing the laser irradiation point at regular intervals across the sample surface and collecting a mass spectrum for each point. Time-of-flight mass spectrometers (TOFMS) are widely used as the mass analyzer for MALDI-MS Imaging because they are well matched for the MALDI ionization process. Ultra-high mass resolution achieving isobaric peak separation is important for lipid profiling using MALDI-Imaging [1, 2]. However, the fine structure of the matrix crystals and small irregularities in the tissue surface flatness can cause peak drift in the collected mass spectra that is caused by slight differences in the starting point of the flight path for the ions at each laser irradiation point. As a result, the typical reflectron type TOFMS systems have a difficult time achieving high mass resolution from spot to spot over a thinly sliced biological surface.

Apps Note High Mass Res using msMicroImager

Imaging mass spectrometry using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-Imaging) has been expanded during the last decade in biological applications, to assess the distribution of proteins, peptides, lipids, drugs, and metabolites in a tissue specimen. In MALDI-Imaging measurements, a laser irradiation point was scanned on a sample surface to acquire a mass spectrum at each point. Analyzing the mass spectra with two-dimensional position information, localization of compounds with inherent molecular weights can be visualized or the mass spectra for certain regions of interests (ROIs) can be created. The JMS-S3000 SpiralTOF (Fig. 1) is a MALDI-TOFMS, which utilizes the JEOL patented spiral ion optical system. It has a 5-10 times longer flight path than the typical reflectron type MALDI-TOFMS. As a result, it can achieve high mass-resolution to separate peaks that have the same nominal mass but have different exact masses (isobaric separation). On the other hand, there are some issues for analyzing high mass resolution and high lateral resolution MALDI-Imaging raw data with common imaging software options such as Biomap.

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.
    © Copyright 2026 by JEOL USA, Inc.
    Terms of Use
    |
    Privacy Policy
    |
    Cookie Preferences