Analytical Instrument Documents

Apps Note MALDI Vision

Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MS Imaging) is a powerful tool for the biochemical analyses of surfaces. Previously, this technique has been used to determine the spatial distribution of hundreds of unknown compounds in thinly sliced tissue sections. The mass spectral images are generated by changing the laser irradiation point at regular intervals across the sample surface and collecting a mass spectrum for each point. Time-of-flight mass spectrometers (TOFMS) are widely used as the mass analyzer for MALDI-MS Imaging because they are well matched for the MALDI ionization process. Ultra-high mass resolution achieving isobaric peak separation is important for lipid profiling using MALDI-Imaging [1, 2]. However, the fine structure of the matrix crystals and small irregularities in the tissue surface flatness can cause peak drift in the collected mass spectra that is caused by slight differences in the starting point of the flight path for the ions at each laser irradiation point. As a result, the typical reflectron type TOFMS systems have a difficult time achieving high mass resolution from spot to spot over a thinly sliced biological surface.

Apps Note High Mass Res using msMicroImager

Imaging mass spectrometry using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-Imaging) has been expanded during the last decade in biological applications, to assess the distribution of proteins, peptides, lipids, drugs, and metabolites in a tissue specimen. In MALDI-Imaging measurements, a laser irradiation point was scanned on a sample surface to acquire a mass spectrum at each point. Analyzing the mass spectra with two-dimensional position information, localization of compounds with inherent molecular weights can be visualized or the mass spectra for certain regions of interests (ROIs) can be created. The JMS-S3000 SpiralTOF (Fig. 1) is a MALDI-TOFMS, which utilizes the JEOL patented spiral ion optical system. It has a 5-10 times longer flight path than the typical reflectron type MALDI-TOFMS. As a result, it can achieve high mass-resolution to separate peaks that have the same nominal mass but have different exact masses (isobaric separation). On the other hand, there are some issues for analyzing high mass resolution and high lateral resolution MALDI-Imaging raw data with common imaging software options such as Biomap.

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.
    © Copyright 2026 by JEOL USA, Inc.
    Terms of Use
    |
    Privacy Policy
    |
    Cookie Preferences