Analytical Instrument Documents

Qualitative Analysis of Grated Daikon Radish by using HS-SPME-GC-QMS and msFineAnalysis iQ

In this MSTips, we report the comparison result of “grated daikon radish” and “diced daikon radish” (n=1 each) using msFineAnalysis iQ.

Peptide Analysis using Field Desorption (FD) of JMS-T2000GC AccuTOF™ GC-Alpha

In this MSTips, we report the results of the analysis of the peptide angiotensin I using FD of the JMS-T2000GC as an example of analysis of a highly polar compound.

Structure Analysis of Polyphenylene Sulfide End Groups using Field Desorption (FD) of JMS-T2000GC AccuTOF™ GC-Alpha

In this MSTips, we report the measurement result of Polyphenylene Sulfide (PPS), an engineering plastic with excellent heat and chemical resistance. It is known that differences in the manufacturing process of PPS appear in the end groups, so structure analysis of the end groups is important. However, PPS is difficult to measure by LC-MS because it is insoluble in common solvents. Therefore, the end groups were estimated using FD, which can measure PPS oligomers even when they are dispersed in a solvent.

Analysis of Polyethyleneimine using Field Desorption (FD) of JMS-T2000GC AccuTOF™ GC-Alpha

In this MSTips, we report the analysis results of a water-soluble polymer polyethyleneimine (PEI), which contains many amines in its structure, by using FD of JMS-T2000GC.

High sensitivity detection method for polycyclic aromatic hydrocarbons using GC-MS/MS

Several methods have been proposed to measure trace amounts of PAHs. Gas chromatography- triple quadrupole mass spectrometry (GC-Triple QMS) is commonly used for high sensitivity measurement methods for specific PAHs in complex matrices. Twenty kinds of PAHs shown in Table 1 (left) were measured using JMS-TQ4000GC (JEOL Ltd.) and those the results are reported in this application note.

Comparison of aromatic compounds in two different red wines by using GC-High resolution TOFMS with the integrated data analysis of msFineAnalysis AI

The characteristics chemical compounds that differ between the two wines were identified by using the differential analysis functionality of msFineAnalysis AI.

Analysis of additive in film by using single-scan mode of GC/MS/MS

In this application, we report on the verification of whether additive analysis in materials can be performed in the same way as conventional QMS using the single QMS mode, and also conducted analysis using msFineAnalysis iQ.

Multifaceted crude oil analysis using GC-EI/FI, blank tube-FI, and FD on JMS-T2000GC

JMS-T2000GC can switch ionization methods without breaking the vacuum by using a EI/FI/FD* combination ion source. In this MSTips, we will introduce crude oil analysis that takes advantage of these ionization methods.

Structure Analysis of Unknown Compound in Lemon Juice by SPME-GC-TOFMS and msFineAnalysis AI

In this MSTips, we report on an example of structure estimation of an unknown compound in lemon juice using msFineAnalysis AI.

Observation of Pd catalytic reactions using an in-situ gas reaction observation system that connects a transmission electron microscope (TEM) and a mass spectrometer (MS)

In this MSTips, we will report on the reaction observation of palladium (Pd), an exhaust gas purification catalyst, by connecting JMS-Q1600GC to JEM-ARM200F equipped with an in-situ sample holder manufactured by Protochips.

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.
    © Copyright 2026 by JEOL USA, Inc.
    Terms of Use
    |
    Privacy Policy
    |
    Cookie Preferences