Analytical Instrument Documents

In this report, we have expanded MALDI-MSI to analyzing a PET film that was exposed to UV radiation. Additionally, a SEM was used to look at the morphological differences in the PET film before and after UV irradiation.

In this study, we used the JMS-S3000 to test several matrices for PSD effects and to measure high resolution mass spectra of intact insulin, ubiquitin and cytochrome C.

In this report, we investigate a MSI visualization method for synthetic polymers that uses Mn, Mw and D as indices for visualization.

In this report, we have combined this method with the Kendrick Mass Defect (KMD) method to effectively visualize polymer series mixtures.

JEOL has developed msFineAnalysis software that integrates both EI and soft ionization data with library search, exact mass, and isotope data.

High Resolution, Time-of-Flight Mass Spectrometer High mass-resolution, which enables differentiation of various classes of hydrocarbons by their exact mass masses, in combination with soft ionization methods, which enable unambiguous detection of hydrocarbon molecular ions, is an extremely powerful tool for petroleum and petrochemical analysis. The JMS-T200GC AccuTOF™ GC-plus is a superior gas chromatograph - high-resolution time-of-flight mass spectrometer (GC-HRTOFMS) system that simultaneously accomplishes high mass-resolution analysis, high mass accuracy, and high-speed data acquisition, satisfying all your needs for petroleum and petrochemical analyses.

The JMS-T100LP AccuTOF™ LC-Express Time-of-Flight Mass Spectrometer is based on our award-winning AccuTOF time-of-flight analyzer platform. The AccuTOF analyzer design employs elegant ion optics and an ADC-based digitizer to deliver a dynamic range exceeding 4 orders of magnitude, without compromising sensitivity, resolution or mass accuracy.

Cocoa butter is the edible fat extracted from cocoa beans that is used in the manufacture of chocolate. Cocoa Butter Equivalents (CBE) are a substance derived from palm oil and shea butter that are used as a substitute for cocoa butter in chocolate. European regulations govern the labeling of chocolate as containing CBE less than 5%. US regulations require that Cocoa Butter Equivalents be specifically labeled with wording such as “chocolate flavored” coating. Analysis of the triglyceride content of chocolate is a quality control measure. Analysis of a standard sample of cocoa butter triglycerides is presented here as an example of the use of the JEOL Q1500 quadrupole GC-MS system for the detection of lipids separated by using a high-temperature GC column (Restek Rtx-65TG).

Fatty acid methyl esters (FAMEs) are crucial for determining the fat content in food. Being environmentally friendly, they are also increasingly used as bio-diesel fuels. Many of the FAMEs are unsaturated with double bonds in the alkyl chains. As the number of double bonds increases (more unsaturation), the EI measurements tend to lack molecular ions. In this work, we measured a standard sample containing multiple FAMEs using EI and FI to detect their molecular ions. The resulting data was further examined by using msFineAnalysis to produce an integrated report for these compounds in which the library database search was combined with the molecular ion exact mass analysis to produce a qualitative identification of these compounds.

Electron ionization (EI) is a hard ionization method that is commonly used with gas chromatography mass spectrometry (GC-MS). The mass spectral fragmentation patterns produced by EI are used for library database searches to identify compounds. Conversely, soft ionization methods like field ionization (FI) tend to produce clear molecular ions with minimal fragmentation. When high-resolution MS is used with these ionization techniques, the accurate masses for the fragment ions produced by EI and the molecular ions produced by soft ionization provide an additional dimension of information for the analytes. Combining the exact mass information with the results of conventional library search can enhance the accuracy of identification compared to the use of library search alone.  In this work, we introduce the msFineAnalysis software and use it to automatically combine data acquired by GC/EI and GC/soft ionization for the qualitative analysis of coffee headspace.

rss

Other Resources

Walkup NMR
  • See how the Delta NMR software allows users to just "walk up" and start NMR experiments
  • Mass Spec Reference Data
  • View our page of useful molecular references for Mass Spec
  • Tutorials (Mass Spec)
  • Documents on the basics of mass spectrometry
  • Delta NMR software Tutorials
  • Videos on how to use the Delta NMR software
  • No-D NMR
  • Description of No-D NMR and how it can be used to eliminate the need for deuterated solvents
  • Non Uniform Sampling (NUS)
  • Description of how NUS is used to greatly reduce the time needed for running NMR experiments
  • NMR Basics
  • Overview of the Basics of NMR Theory
  • NMR Magnet Destruction
  • See our presentation of the slicing open of a JEOL Delta-GSX 270 MHz NMR Magnet
  • NMR Training
    Basic Operations and System Management for JEOL NMR Users
    Mass Spec Training
    Learn more about spectrometer operation and maintenance, data collection and processing, and advanced MS software operation.
    JEOLink NMR Newsletter
    We publish and send out this NMR newsletter to our customers. They can also be viewed here.
    Mass Media Newsletter
    We publish and send out this Mass Spec newsletter to our customers. They can also be viewed here.